946, GIDC, Makarpura, Vadodara, India inq@polyvalve.com
LINED VALVES › SAMPLING VALVE

Sampling Valve — Sandwich Wafer

Compact wafer-style sampling valve installed between existing flange pairs. Minimal pipe-length impact, ideal for retrofitting existing lines.

1" – 2"

Size Range

Wafer (between flanges)

Connection

60mm / 2.36"

Face to Face

SMVS

Code Prefix

OVERVIEW

Sandwich Wafer Sampling Valve Configuration

The Sandwich Wafer sampling valve is designed for installation between existing flange pairs, requiring only the addition of slightly longer through-bolts. With a face-to-face of just 60mm, it adds almost no length to the pipeline.

This configuration is the preferred choice for retrofitting sampling capability into existing lines — particularly in plants where pipe re-routing is impractical or where space constraints prevent the longer flanged-end body.

Wetted parts are identical to the Flanged variant — PTFE chevron packing, PTFE socket, PTFE spindle, and PFA-lined investment-cast WCB body — ensuring the same media compatibility and operator safety.

TECHNICAL DATA

Specifications, Parts, Dimensions

Specifications

Design StdManufacturer's Standard
Shell DesignANSI B 16.34
Face to Face Dim.Manufacturer's Standard (60mm / 2.36")
Flange Connection RatingANSI B 16.5 150# / DIN PN 10
Testing StandardBS EN 12266-1
ConnectionWafer (between existing flanges)

Part List

Part No.DescriptionMaterial of ConstructionQty
1BodyASTM A 216 GR. WCB + PFA Lined1
2Material PortPTFE1
3Chevron PackingPTFE1
4SocketPTFE1
5Lock PlateSS 3041
6Companion FlangeSS 3041
7FastenersSS 3043
8SpindlePTFE1

Dimension Table

All dimensions in inches and millimeters.

Size (NB) A ±0.12 L1 ±0.12 d ±0.02 d1 d2 D1 ±0.04 D3 ±0.04
INCHMM INCHMM INCHMM INCHMM INCHMM INCHMM INCHMM
1"8.272102.36600.79200.2460.71182512.4462
2"9.052302.36601.97500.2460.71183.62923.7495

Valve Net Weight

SizeWeight (kg)Weight (lb)
1"1.804.00
2"3.006.60

How to Read Valve Code

Example code: SMVSC1PTL1XXF1LX01

FieldSelectionCode
Valve TypeSampling Valve SandwichSMVS
CastingASTM A 216 GR. WCBC1
TrimPTFEPT
Lining MaterialPFAL1
SeatIntegral PFAXX
FastenerSteel PlatedF1
OperationLeverL
Locking ArrangementNot ApplicableX
Size1"01

Tests Performed

TestEN 12266-1 (1" – 2")
High Pressure Shell Test (Hydro)75 PSI
Spark Test20 KVDC

Materials Available

ComponentOptions Available
CastingsASTM A 216 GR. WCB, ASTM A 351 GR. CF8 / CF8M, Hastelloy C 276 / Inconel
Lining MaterialsPFA / FEP / ETFE / PVDF / PPH

Pressure - Temperature Graph

Operating envelope across both Flanged and Sandwich configurations.

Pressure Temperature Graph
OUR PORTFOLIO

Related Products

READY TO ORDER?

Order the Sandwich Wafer Variant

Tell us your line size, lining preference, and operating conditions — we’ll spec the exact Sandwich Wafer sampling valve for your line.