Control Lined Ball Valve
Pneumatically- or Electrically-Actuated PFA-Lined Ball Valve for Automated On/Off and Modulating Service
0.5" – 12"
Size Range
Pneumatic / Electric
Actuation
On-Off & Modulating
Control Function
PFA / FEP / PVDF
Lining
Quarter-Turn Control Ball Valves for Corrosive Process Loops
UNP’s Control Lined Ball Valve combines our proven lined ball valve body with a factory-fitted pneumatic or electric actuator. Both Reduced Port and Full Port designs are available, and the ISO 5211 mounting pad accommodates virtually any aftermarket actuator if you want to specify your own.
For on/off automated isolation duty, the quarter-turn ball valve is the fastest and lowest-torque option. For modulating throttle control, pair it with a smart positioner (HART or Profibus) on the pneumatic actuator. V-port balls are available for improved low-flow control characteristics.
The full-port floating ball gives full unobstructed bore for non-fouling flow paths. Reduced port (with stem-integral ball) is more compact and suited to smaller actuator sizes.
Why Choose This Control Valve
- ✓Quarter-turn for fast actuation
- ✓Reduced & Full Port designs
- ✓ISO 5211 mounting standard
- ✓V-port ball available for modulating control
- ✓Chevron PTFE stem seal — zero leakage
Choose Your Actuator Type
Each valve ships fully assembled with the actuator type and accessories that fit your control strategy.
Pneumatic
Spring-return fail-safe and double-acting cylinders. Fastest response, preferred for safety-critical service.
Electric
Motorized actuators with 4–20 mA modulating or on/off control. For sites without instrument air.
With Smart Positioner
Pneumatic actuator + digital positioner (HART/Profibus) for precise modulating throttle control.
Specifications, Materials, Testing
Valve Body Specifications
| Valve Design Standard | BS EN 17292 |
| Shell Design | ANSI B 16.34 |
| Size Range | 0.5" – 12" |
| Connection | Flanged, RF (Wafer for Butterfly) |
| Testing Standard | API 598 / BS EN 12266-1 |
| Operating Temperature | -40°F to 450°F (PFA) — depends on lining material |
Actuator Specifications
| Parameter | Specification |
|---|---|
| Mounting Standard | ISO 5211 (rotary) / ISO 5210 (linear) |
| Air Supply (Pneumatic) | 4 – 8 bar clean dry instrument air |
| Power Supply (Electric) | 24V DC, 110/220V AC, 380/415V 3-Phase |
| Control Signal | 4–20 mA / 0–10V / On-Off / HART (optional) |
| Fail-Safe Action | Spring Return — Fail Open / Fail Close / Stay Put |
| Enclosure Rating | IP67 standard / IP68 / ATEX Zone 1 (Ex d) on request |
Available Accessories
| Accessory | Function |
|---|---|
| Positioner | Smart digital positioner with HART / FF / Profibus protocols |
| Solenoid Valve | 3/2 or 5/2 pilot — NAMUR mounting standard |
| Limit Switch Box | Mechanical or proximity switches with visual indicator |
| Filter Regulator | Air filtration + pressure regulation for pneumatic supply |
| Volume Booster | For high-flow-rate stroking of large actuators |
Valve Body Materials
| Component | Options Available |
|---|---|
| Body Casting | ASTM A 216 GR. WCB / A 351 GR. CF 8 / CF 8M / A 890 GR. 4A (CD3MN) / Super Duplex |
| Lining Materials | PFA / FEP / ETFE / PVDF / PPH / ECTFE / Antistatic PFA |
| Flange Rating | ANSI B 16.5 150# / 300# / DIN PN 10 / 16 / 25 / JIS |
Testing & Certification
| Test | Standard / Specification |
|---|---|
| Hydrostatic Shell Test | API 598 / BS EN 12266-1 (100% sampled) |
| Seat Leakage Test | API 598 Class VI / Bubble-Tight |
| Spark Test (Lined Components) | 20 KVDC |
| Actuator Function Test | Full stroke + signal response verification |
| Certifications | ISO 9001:2015 / CE / PED 1128 / SIL-3 (on request) |
Other Control Lined Valves

Control Lined Butterfly Valve
CONTROL LINED VALVES

Control Plug Valve
CONTROL LINED VALVES

Control Lined Diaphragm Valve
CONTROL LINED VALVES

Control Globe Control Valve
CONTROL LINED VALVES
Order Your Control Lined Ball Valve