Control Lined Diaphragm Valve
Bubble-Tight PFA-Lined Diaphragm Valve with Pneumatic or Electric Actuation for Sterile & Ultra-Pure Service
0.5" – 10"
Size Range
Pneumatic / Electric (Linear)
Actuation
Bubble-Tight On-Off
Control Function
PFA / FEP / PVDF
Lining
Actuated Diaphragm Valves for Pharma, Semicon, and Sterile Process
UNP’s Control Lined Diaphragm Valve provides bubble-tight automated isolation in sterile and ultra-pure service lines. The diaphragm fully separates the wetted media from the actuator and stem — no stem packing, no leak path to atmosphere, and no contamination risk to the process.
Pneumatic or electric linear actuators (ISO 5210 standard) are factory-fitted to the bonnet. The actuator compresses the diaphragm against the weir seat to shut off flow, then retracts to allow full-bore flow when open. Pneumatic spring-return options provide fail-safe close on air loss.
Diaphragm options include standard TFM+EPDM (double layer) and PTFE+PVDF+EPDM (triple layer) for permeation-resistant chlorine service.
Why Choose This Control Valve
- ✓Bubble-tight zero-leak shutoff
- ✓Wetted parts fully isolated from actuator
- ✓Double / Triple-layer diaphragm options
- ✓Spring-return fail-safe close standard
- ✓Sterile / FDA-grade lining options
Choose Your Actuator Type
Each valve ships fully assembled with the actuator type and accessories that fit your control strategy.
Pneumatic
Spring-return fail-safe and double-acting cylinders. Fastest response, preferred for safety-critical service.
Electric
Motorized actuators with 4–20 mA modulating or on/off control. For sites without instrument air.
With Smart Positioner
Pneumatic actuator + digital positioner (HART/Profibus) for precise modulating throttle control.
Specifications, Materials, Testing
Valve Body Specifications
| Valve Design Standard | BS EN 13397 |
| Shell Design | ANSI B 16.34 |
| Size Range | 0.5" – 10" |
| Connection | Flanged, RF (Wafer for Butterfly) |
| Testing Standard | API 598 / BS EN 12266-1 |
| Operating Temperature | -40°F to 450°F (PFA) — depends on lining material |
Actuator Specifications
| Parameter | Specification |
|---|---|
| Mounting Standard | ISO 5211 (rotary) / ISO 5210 (linear) |
| Air Supply (Pneumatic) | 4 – 8 bar clean dry instrument air |
| Power Supply (Electric) | 24V DC, 110/220V AC, 380/415V 3-Phase |
| Control Signal | 4–20 mA / 0–10V / On-Off / HART (optional) |
| Fail-Safe Action | Spring Return — Fail Open / Fail Close / Stay Put |
| Enclosure Rating | IP67 standard / IP68 / ATEX Zone 1 (Ex d) on request |
Available Accessories
| Accessory | Function |
|---|---|
| Positioner | Smart digital positioner with HART / FF / Profibus protocols |
| Solenoid Valve | 3/2 or 5/2 pilot — NAMUR mounting standard |
| Limit Switch Box | Mechanical or proximity switches with visual indicator |
| Filter Regulator | Air filtration + pressure regulation for pneumatic supply |
| Volume Booster | For high-flow-rate stroking of large actuators |
Valve Body Materials
| Component | Options Available |
|---|---|
| Body Casting | ASTM A 216 GR. WCB / A 351 GR. CF 8 / CF 8M / A 890 GR. 4A (CD3MN) / Super Duplex |
| Lining Materials | PFA / FEP / ETFE / PVDF / PPH / ECTFE / Antistatic PFA |
| Flange Rating | ANSI B 16.5 150# / 300# / DIN PN 10 / 16 / 25 / JIS |
Testing & Certification
| Test | Standard / Specification |
|---|---|
| Hydrostatic Shell Test | API 598 / BS EN 12266-1 (100% sampled) |
| Seat Leakage Test | API 598 Class VI / Bubble-Tight |
| Spark Test (Lined Components) | 20 KVDC |
| Actuator Function Test | Full stroke + signal response verification |
| Certifications | ISO 9001:2015 / CE / PED 1128 / SIL-3 (on request) |
Other Control Lined Valves

Control Lined Ball Valve
CONTROL LINED VALVES

Control Lined Butterfly Valve
CONTROL LINED VALVES

Control Plug Valve
CONTROL LINED VALVES

Control Globe Control Valve
CONTROL LINED VALVES
Order Your Control Lined Diaphragm Valve
Tell us your line size, lining preference, actuation type, and accessories — we’ll spec the exact control valve package in 24 hours.