946, GIDC, Makarpura, Vadodara, India inq@polyvalve.com
LINED PIPE & FITTINGS

Lined Reducer

Concentric Reducers for Smooth Inline Diameter Changes

1/2" – 12"

Size Range

Flanged, RF

Connection

Mfr's / ANSI B 16.5

Design Std

PFA / FEP / PVDF

Lining

OVERVIEW

Concentric Reducers for Lined Pipelines

UNP’s Lined Reducer provides smooth, low-turbulence diameter transitions inline between two flanged lined-pipe sections. The concentric (symmetric) design keeps the pipe centerline aligned through the transition — the standard choice for vertical runs and most horizontal applications.

Investment-cast WCB body is lined with PFA, FEP, PVDF, ETFE, or PPH throughout the conical transition. The lining is uniformly thick along the taper, avoiding the local thinning that often occurs with transfer-molded reducers.

For applications requiring offset transitions (e.g., to maintain a constant bottom-of-pipe elevation in horizontal sludge lines), eccentric reducers are available on request.

Why Choose This Fitting

  • Concentric (symmetric) reduction
  • Smooth conical transition (low turbulence)
  • Investment cast PFA-lined body
  • Eccentric option available on request
  • Sizes 1.5" x 1" through 12" x 10"
TECHNICAL DATA

Dimensions, Materials, Tests

Dimensional Table — Concentric Reducer

All dimensions in inches and millimeters.

Main SizeReduced SizeLength (mm)Lining Thk (mm)Net Weight (kg)
1.5" x 1"1.5" x 1"893.21.8
2" x 1"2" x 1"893.52.4
2" x 1.5"2" x 1.5"893.52.4
3" x 1.5"3" x 1.5"1274.04.5
3" x 2"3" x 2"1274.04.5
4" x 2"4" x 2"1524.57.0
4" x 3"4" x 3"1524.57.0
6" x 3"6" x 3"1785.512.0
6" x 4"6" x 4"1785.512.0
8" x 4"8" x 4"2295.518.0
8" x 6"8" x 6"2295.518.0
10" x 8"10" x 8"2546.528.0
12" x 8"12" x 8"3056.540.0
12" x 10"12" x 10"3056.540.0

Materials Available

ComponentOptions Available
Body CastingASTM A 234 GR. WPB / WPC, ASTM A 403 GR. WP 316 / WP 316L
Lining MaterialsPFA / FEP / ETFE / PVDF / PPH / ECTFE / Antistatic PFA
Standard Flange RatingANSI B 16.5 150# / DIN PN 10 / JIS

Tests Performed

TestStandard / Result
Spark Test (Lined Components)20 KVDC
Hydrostatic TestBS EN 12266-1
Visual / Dimensional Inspection100% Sampled
OUR PORTFOLIO

Other Lined Fittings

Lined Elbow

LINED PIPE & FITTINGS

Lined Equal Cross

LINED PIPE & FITTINGS

Lined Tee

LINED PIPE & FITTINGS

Lined Reducing Flange

LINED PIPE & FITTINGS

READY TO ORDER?

Order the Lined Reducer

Tell us your main and reduced sizes plus lining preference — we’ll spec the exact reducer for your line.

Scroll to Top